[The Advanced Damping Device] comes in six types and two series for newly constructed buildings and reinforcement, which provide perfectly suited damping performance for various buildings. They can reverse up-down and left-right and there are 24 types of installation modes.
They flexibly respond to suit the pillar spacing, floor height and aperture of the buildings.
@
@
300 Series
This series consist of components that use an oil damper that has the damping force of 200~300kN. There are two types of oil dampers; KY530 with a 110mm stroke with a _177mm outer diameter and KY330 with a 80mm stroke with a _165mm outer diameter. The brace comes in a smart design and is thin with a_159mm outer diameter.
500 Series
This series consists of components that use an oil damper that has the damping force of 300~500kN. KY550 with 110mm stroke with a _177mm outer diameter is used in the main oil damper. The brace has a 190.7mm outer diameter and does not look intimidating even when used indoors.
@
©As there are often difficulties installing such reinforcement structures internally surrounding frames are connected by bolts.
@
Installation type
There are two installation methods; one is to set up one unit to either a newly constructed building or for the use in earthquake reinforcement. The second installation method is to set up *two units. The second installation method allows you to choose a unit where the oil damper is installed on the internal side depending on the position of the entrance/exit. The diagram on the left shows the device for earthquake reinforcement, but when it is installed in a newly constructed building the Advanced Damping Device is installed by attaching the connecting hardware to the corner of the pillar-beam or in the middle of the beam.
_In case of earthquake reinforcement, the 2-unit method of the 500 Series is not suitable as there would be too much stress on the building frame.
@
Measure of damping force
The measure of damping force per set device is the value obtained from multiplying the average amplification scale to the oil dampers damping force.
@
Measure of damping force
The measure of damping force per set device is the value obtained from multiplying the average amplification scale to the oil dampers damping force. Example: When the average amplification scale equals 2.5.
@
@ Series Oil Damper Damping Force (kN) Installation Type Damping force
ikNj
1 300 200`300 1 500`750
2 300 200`300 2 1000`1500
3 500 300`500 1 750`1250
@